Here are relevant prior publications about ACIS and XIS instrument performance, on the ground and in orbit.


Leaky Buckets related publications

Presentation at IACHEC, April 2011
https://wikis.mit.edu/confluence/download/attachments/61572295/Grant.LeakyBuckets.pdf

Poster at AAS (ACIS only), May 2011
AAS11.poster.pdf

Poster at Suzaku Science Conference, July 2011
Suzaku11.poster.letter.pdf

XIS Papers and Resources

XIS CTI Monitoring:

LaMarr, et al. 2008, Proc SPIE, 7011, 66  PDF
Front- and back-illuminated x-ray CCD performance in low- and high-Earth orbit: performance trends of Suzaku XIS and Chandra ACIS detectors
http://adsabs.harvard.edu/abs/2008SPIE.7011E..66L

LaMarr, et al. 2006, Proc SPIE, 6270, 56
Performace trends for the x-ray imaging spectrometer on Suzaku
(1 year of flight data, no charge injection, cal source only)
http://adsabs.harvard.edu/abs/2006SPIE.6270E..56L

XIS CTI Correction:

Uchiyama, H., Ozawa, M., Matsumoto, H., et al. 2009, PASJ, 61, 9
New CTI Correction Method for the Spaced-Row Charge Injection of the Suzaku X-Ray Imaging Spectrometer

Ozawa, M., Uchiyama, H., Matsumoto, H., et al. 2009, PASJ, 61, 1
Energy-Scale Calibration of the Suzaku X-Ray Imaging Spectrometer Using the Checker Flag Charge Injection Technique in Orbit

XIS Charge Injection Performance:

Nakajima, H., Yamaguchi, H., Matsumoto, H., et al. 2008, PASJ, 60, 1
Performance of the Charge-Injection Capability of Suzaku XIS

Ozawa, et al. 2008, Proc SPIE, 7011, 65
Flight calibration of the Suzaku XIS using the charge injection technique
2008SPIE.7011E..65O

Bautz, M. W., LaMarr, B. J., Miller, E. D., et al. 2007, SPIE, 6686
Mitigating CCD radiation damage with charge injection: first flight results from Suzaku

Uchiyama, H., Hyodo, Y., Yamaguchi, H., et al. 2007, SPIE, 6686
The onboard calibration for the spaced-row charge injection of the Suzaku XIS

XIS Background:

Tawa, N., Hayashida, K., Nagai, M., et al. 2008, PASJ, 60, 11
Reproducibility of Non-X-Ray Background for the X-Ray Imaging Spectrometer aboard Suzaku

XIS General Information, Ground and Orbital Calibration:

Hayashida, Torii, Namiki, et al. 2007, PTPS, 169, 316
Orbital Calibration of the XIS

Koyama, Tsunemi, Dotani, et al. 2007, PASJ, 59, 23
X-Ray Imaging Spectrometer (XIS) on Board Suzaku

Suzaku Technical Description
http://heasarc.gsfc.nasa.gov/docs/suzaku/prop_tools/suzaku_td/suzaku_td.html

Suzaku XIS Pocket Guide
http://www.astro.isas.jaxa.jp/~tsujimot/pg_xis.pdf

XIS Celestial Calibration Sources:

Plucinsky, et al. 2008, Proc SPIE, 7011
The SMC SNR 1E0102.2-7219 as a Calibration Standard for X-ray Astronomy in the 0.3-2.5 keV Bandpass
(arXiv:0807.2176)


ACIS Papers and Resources

The new CXC Calibration has many good references and links to presentations at Calibration Workshops. It's not officially
live yet, but can be found here:
http://asc.harvard.edu/cal/Acis/detailed_info_new.html

ACIS CTI monitoring: 

(CTI, trailing charge, correcting CTI for bkg and temperature)

LaMarr, et al. 2008, Proc SPIE, 7011, 66  PDF
Front- and back-illuminated x-ray CCD performance in low- and high-Earth orbit: performance trends of Suzaku XIS and Chandra ACIS detectors
http://adsabs.harvard.edu/abs/2008SPIE.7011E..66L

Grant, et al. 2005, Proc. SPIE, 5898  PDF
Long-term trends in radiation damage of Chandra X-ray CCDs
http://adsabs.harvard.edu/abs/2005SPIE.5898..201G
(The poster outside CEG's office updates some of this.)

The continually updated monitoring web pages:
http://space.mit.edu/~cgrant/monitor.html

ACIS CTI Correction:

The PSU CTI correction algorithm (short version):
Townsley, et al. 2000, ApJ, 543, L139
Mitigating charge transfer inefficiency in the Chandra X-ray Observatory Advanced CCD Imaging Spectrometer
http://adsabs.harvard.edu/abs/2000ApJ...534L.139T

The PSU CTI correction algorithm (long version):
Townsley, et al. 2002, NIMPA, 486, 751
Modeling charge transfer inefficiency in the Chandra Advanced CCD Imaging Spectrometer
http://adsabs.harvard.edu/abs/2002NIMPA.486..751T

CEG CTI correction algorithm (this is what acis_process_events uses):
Grant, et al. 2004, Proc. SPIE, 5501
A charge transfer inefficiency correction model for the Chandra X-ray CCDs
http://adsabs.harvard.edu/abs/2004SPIE.5501..177G

CTI temperature dependence (no correction algorithm yet):
Grant, et al. 2006, Proc. SPIE 6276
Temperature dependence of charge transfer inefficiency in Chandra X-ray CCDs
http://adsabs.harvard.edu/abs/2006SPIE.6276E..48G

CTI temperature dependence correction:
Grant, 2007, presentation at Chandra Cal Workshop
Correcting for the temperature dependence of ACIS charge transfer inefficency
http://cxc.harvard.edu/ccr/proceedings/07_proc/presentations/grant/

CTI correction with sacrificial charge: (not implemented)
Grant, et al. 2003, Proc. SPIE 4851
Sacrificial charge and the spectral resolution performance of the Chandra Advanced CCD Imaging Spectrometer
http://adsabs.harvard.edu/abs/2003SPIE.4851..140G

ACIS Background:

Grant et al. 2002, ASP Conf. Proc., 262
The Temporal Characteristics of the Chandra X-ray Observatory High Energy Particle Background
http://adsabs.harvard.edu/abs/2002ASPC..262..401G

Markevitch et al. 2003, ApJ, 583, 70
Chandra Spectra of the Soft X-ray Diffuse Background
http://adsabs.harvard.edu/abs/2003ApJ...583...70M

ACIS General Information

Garmire et al. 2003, SPIE, 4851, 28
Advanced CCD imaging spectrometer (ACIS) instrument on the Chandra X-ray Observatory
http://adsabs.harvard.edu/abs/2003SPIE.4851...28G

Chandra radiation environment:

Grant, Lamarr, Bautz, O'Dell, 2010, Proc. SPIE, 7732
Using ACIS on the Chandra X-ray Observatory as a particle radiation monitor
http://adsabs.harvard.edu/abs/2010SPIE.7732E..80G

O'Dell, et al. 2008, Proc. SPIE, 6686
Managing radiation degradation of CCDs on the Chandra X-ray Observatory III
http://adsabs.harvard.edu/abs/2007SPIE.6686E...3O

O'Dell, et al. 2005, Proc. SPIE, 5898
Managing radiation degradation of the CCDs on the Chandra X-ray Observatory II
http://adsabs.harvard.edu/abs/2005SPIE.5898..212O

O'Dell, et al. 2003, Proc. SPIE, 4851
Managing radiation degradation of the CCDs on the Chandra X-ray Observatory
http://adsabs.harvard.edu/abs/2003SPIE.4851...77O

(and others, but these are the main ones)

Prigozhin, et al. 2000, Proc SPIE, 4012, 720
Radiation damage in the Chandra x-ray CCDs
http://adsabs.harvard.edu/abs/2000SPIE.4012..720P

Prigozhin, et al. 2000, Proc SPIE, 4140, 123
Characterization of the radiation damage in the Chandra x-ray CCDs
http://adsabs.harvard.edu/abs/2000SPIE.4140..123P

Miscellaneous papers on CTI after bakeout, contamination, etc.







  File Modified
PDF File Suzaku11.poster.letter.pdf Aug 02, 2011 14:04 by Catherine E Grant
PDF File AAS11.poster.pdf Jun 20, 2011 14:22 by Catherine E Grant
Text File leakyBuckets.txt from Bev's notes file Jan 21, 2011 10:00 by Eric D Miller
PDF File 2005_grantetal.pdf Jan 20, 2011 12:20 by Eric D Miller
PDF File 2008_lamarretal.pdf Jan 20, 2011 11:09 by Eric D Miller
  • No labels