BCR localizes on membraneB-Cells of any kind were unavailable for use as a positive control for this experiment. Moreover the mKate transfection marker in our control did not show as much red fluorescence as was expected. The cytometry data remains inconclusive but the BCR plots suggest that there was BCR localization. Moreover the microscopy clearly shows membrane localization of the BCR in both permeablized and non-permeablized cells. This experiment will be repeated once B-Cells Become available. Additionally in this experiment no untransfected unstained control was planned into the plate and thus we had to collect one on very short notice. For the next experiment this control will be planned into the experiment. |