Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Notes from IEEE:

- change in temperature less than 2K across tank [nearly isothermic] 

-24 hour turnover rate of fluid from cryogenic pump

  • Sensors:
    • Static 
    • Floating around 

Would a moving sensor affect the thermodynamics/temperature of the liquid?

Look into: 

  • https://www.realpars.com/blog/thermocouple Thermocoupling 
  • What homogeneous temperature are we trying to achieve? [so that we know what temperature the sensors have to withstand]
  • Is cost an important factor to the sensor?
  • What is the goal of the sensor suites across the multiple tests?

...

  •  
    • Is it measuring temperature for all of them 
  • Optimal Placements
    • Within physical mixing device (minimize the # of extra sensors within the tank]
  • Understand what each test is doing c

Tests our sensor setups have to perform in:

  • Cryocooler Performance Test
  • Baffle & Pump Cryogenic Flow Test 
  • Thermal Subsystem Demo 
  • Mixing Subsystem Demo 


Thermal Subsystem Demo: 

Testing whether a cryogenic tank wrapped in insulation and cooled by a cryocooler can keep its liquid from boiling away in a space-like vacuum environment.

How-to-test:

  • Boil-off flow: mass-flow meter on vent line (gas phase)

  • Mass loss: weigh the filled tank before/after

  • Level sensor (capacitance/RTD stack) to track liquid height over time

  • Temperatures: many thermocouples on tank wall, loop inlet/outlet, MLI outer surface, heater panels

...