Equipment Booking
In order to ensure that you are able to use the equipment, please book it through this wiki page. Write your name and the time where you wish to use the microscope. Example: Name1 9am-12pm; Name2 1pm-4p
- Microscope 1
- Fluorescence, brightfield, phase contrast
- IPLab control
- Cooke PCO 1600 (CCD; 1600x1200 7.4 um pixels; 30 fps @ full frame, 50 fps binned 2x2)
(http://www.cookecorp.com/sensitive-cameras/pco1600/) - Nikon Zyla (CMOS 2560 x 2160 6.5 µm pixels)
- Hamamatsu Orca II (C4742-98-24 ERG; CCD; 1344x1024 6.45 um pixels; 5.6 fps in high-speed mode, 0.83 fps in high-precision mode @ full frame)
(http://sales.hamamatsu.com/assets/pdf/hpspdf/C4742-98-24ER.pdf) - Computer: Raid 0 harddrive.
- Microscope 2
- Fluorescence, brightfield, darkfield, phase contrast
- Nikon NIS-Elements control
- Andor iXon-885 (EMCCD; 1004x1002 8 um pixels; 30 fps @ full frame, 60 fps binned 2x2)
(http://www.andor.com/scientific_cameras/ixon_emccd_camera/)
- Microscope 3 - NO CAMERA COMPUTER CONTROL YET
- Brightfield, darkfield, phase contrast
- Nikon NIS-Elements control
- Andor Neo sCMOS (CMOS; 2560x2160 6.5 um pixels; 100 fps @ full frame, 400 fps @ 512x512528x512)
(http://www.andor.com/scientific_cameras/neo_scmos_camera/)
- Photron SA3 60K -High-Speed Camera
- Photron PFV software through gigabit ethernet connection (NOT controlled by IPLab or Nikon NIS-Elements)
- CMOS; 1024x1024 17 um pixels; 1000 fps @ full frame, 3000 fps @ 512x512
(http://www.photron.com/index.php?cmd=product_general&product_id=6&product_name=FASTCAM+SA3)
Syringe pump P = Harvard Apparatus Programmable; I/W = Infuse/Withdraw; (n): number of syringes
Nov 30 - Dec 6 | Scope 1 | Scope 2 | Scope 3 | Scope 4 | photron | pumpP | pump I/W | pump I/W | pump PicoPlus | hasp | |||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Mon 30 | Mehdi 11am-6pm |
|
| ||||||||||||
Week of Oct 10- Oct 16 | Microscope 1 | Microscope 2 | Microscope 3 | Photron Camera | Syringe Pump P (10) | Syringe Pump I/W (10) | Syringe Pump I/W (10) | Syringe Pump I (2) | |||||||
Monday | Diana 12 PM - 6 PM | Hongchul 9am-7pm |
| Mehdi 11am-6pm |
| Hongchul 9am-7pm | Jane/Steve | Tuesday | Diana 12 PM - 6 PM | Melissa 10am-2pm |
| ||||
Tue 1 | Mehdi 11am-6pm |
|
|
| Mehdi Steve 11am-6pm |
|
|
| Jane/Steve | ||||||
Wed 2 | Cherry 1pm - 4pm |
|
| Wednesday | Yutaka 12pm-7pm | Hongchul 9am-8pm |
|
| Hongchul 9am-8pm | Jane/Steve | Thursday | Yutaka5 pm-7pm |
| ||
Thu 3 | Mehdi 11am Kwangmin 9am-6pm Gaston 6pm-10pm | Orr 1-4 PM |
|
| Mehdi 11am-6pm Gaston 6pm-10pm |
| Jane/Steve |
|
| ||||||
Fri 4 | Mehdi 11am-6pm |
|
|
| Mehdi 11am-6pm |
| Friday | Orr 9AM-12 PM | Hongchul (all day) | Kwangmin 9am-6pm |
|
| |||
Sat 5 | Gaston 12pm-8pm Hongchul (all day) |
| Saturday |
| Gaston 12pm-8pm | Hongchul (all day) |
|
| Hongchul (all day) | ||||||
Sun 6 (LAST DAY to do experiments) | Gaston 12am-8pm |
| Sunday | Hongchul (all day) | Gaston 12am-8pm |
|
| Hongchul (all day) |
| Scope | Week of Oct 17- Oct 23 | Microscope 1 | Microscope Scope 2 | Microscope Scope 3 | Photron Camera | Syringe Pump P (10) | Scope 4 | photron | pumpP | pump Syringe Pump I/W (10)Syringe Pump | pump I/W (10) | Syringe Pump I (2) | pump PicoPlus | hasp | ||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Mon | Do Not Use This Table |
|
|
|
|
|
|
| |||||||||
Tue | Copy and Paste Only |
| Monday | Yutaka 12pm-7pm | Hongchul (all day) |
|
| Hongchul (all day) |
|
|
| ||||||
Wed |
| Tuesday | Kwangmin (computer only) | Melissa 10-6pm | Kwangmin 9am-6pm |
|
| Melissa 10-6pm | Melissa 10-6pm (I would like to use 2 pumps, but can certainly work with 1 if anyone else needs this one.) |
| Wednesday | Yutaka 12pm-7pm | Melissa 9:30-2pm
|
|
| ||
Thu |
|
| Melissa 9:30-2pm |
| Thursday |
| Steve 8pm to o/n |
|
| ||||||||
Steve 8pm to o/n Fri |
|
| Friday | Steve until 5pm |
| Hongchul 1pm- o/n |
| Steve until 5pm |
| ||||||||
Sat Hongchul 1pm- o/n |
|
| Saturday | Hongchul (all day) |
|
| Hongchul (all day) |
| |||||||||
Sun |
| Sunday | Hongchul (all day) |
|
|
| Hongchul (all day) |
|