Common selection, cuts will be applied to W, Z-analysis and not varied

( unless explicitly stated)

  1. Run selection: run list (423 runs) , muDst list (8551 files) , available # of events: input=1.30e6, L2wET=9.65e5
  2. use SL09b muDst after BHT3 'notch' problem was fixed, beginGMT= 2009-03-28 12:34:27, comprising ~80% of recorded data
    • RHIC fill range: F10448 - F10536
    • STAR run range: R10086140 - R10103046
      • skip runs w/ badly functioning TPC (~no vertices found) : R10084013, R10088103, R10081024, R10095032, R10085022, R10088060, R10085103, R10087007, R10093049, R10085118
  3. run analysis on muDst's
    1. access TRG,TPC,BTOW,BSMD directly from muDst containers
    2. apply calibrations from DB 'by hand' in analysis code
  4. Trigger bits requirement
    1. BHT3 trig ID: 23054[01] or small IDs for some runs
    2. L2W trig ID: 23060[01] or small IDs
    3. L2-bit1 (on line value was ET>13 GeV)
    4. count L2-bit0 (random accept of BHT3) for absolute 'seen' cross section
  5. Reco prim vertex requirements
    1. rank>0
    2. | z-vertex | <100 cm
  6. Reco TPC track requirements
    1. prim tracks belong to selected prim vertex
    2. (flag=301 for primary) or (flag=101 for global) component
    3. if primary is valid but its global pointer is NULL skip the primary track, but keep the rest of the event
    4. nFit/nPoss>0.51
    5. for high energy electron candidate require additional
      1. nFitPoints>=15
      2. if track PT>10 GeV/c assume it is 10 GeV/c
    6. do not use TPC dEdX information for SL09b events
  7. BTOW: use ideal gains, actual status tables & pedestals , 'ofl' flavor for all, no time stamp set in the user code
    1. assume tower is dead if status!=1
    2. assume tower ADC=0 if (rawADC-ped)< [3*sigPed or 8 counts]
  8. BSMD use Willi's 2009 calibration , no time stamp set in the user code
    1. use relative gains, DB flavor=Wbose
    2. use status bits from DB , flavor=ofl
    3. use pedestal residua from DB , flavor=ofl
    4. assume strip is dead if status not in range [1,19]
    5. assume strip ADC=0 if (ZS ADC-pedRes)< 3* sigPed
    6. for the record: must use custom absolute calibration ( ADC--> energy), describe it

Barrel DB tables loaded for Run9 data processing

(example for run 10096139)

StInfo: loaded a new bemcPed table with beginTime 2009-04-07 03:08:21 and endTime 2009-04-07 16:45:44
StInfo: loaded a new bemcStatus table with beginTime 2009-04-07 01:15:26 and endTime 2009-04-07 16:38:34
StInfo: loaded a new bemcCalib table with beginTime 1999-01-01 00:11:00 and endTime 2037-12-31 12:00:00
StInfo: loaded a new bemcGain table with beginTime 1999-01-01 00:08:00 and endTime 2037-12-31 12:00:00

StInfo: loaded a new bsmdePed table with beginTime 2009-04-06 11:04:26 and endTime 2009-04-07 15:18:54
StInfo: loaded a new bsmdeStatus table with beginTime 2009-04-06 11:04:26 and endTime 2009-04-07 15:18:54
StInfo: loaded a new bsmdeCalib table with beginTime 2008-12-15 00:00:00 and endTime 2037-12-31 12:00:00
StInfo: loaded a new bsmdeGain table with beginTime 1999-01-01 00:08:00 and endTime 2037-12-31 12:00:00

StInfo: loaded a new bsmdpPed table with beginTime 2009-04-06 11:04:26 and endTime 2009-04-07 15:18:54
StInfo: loaded a new bsmdpStatus table with beginTime 2009-04-06 11:04:26 and endTime 2009-04-07 15:18:54
StInfo: loaded a new bsmdpCalib table with beginTime 2008-12-15 00:00:00 and endTime 2037-12-31 12:00:00
StInfo: loaded a new bsmdpGain table with beginTime 1999-01-01 00:08:00 and endTime 2037-12-31 12:00:00

  • No labels