These motors are tested on "Henrietta" our yellow 54mm and 98mm test stand.

Test #DateSiteResult
XB-54-1G #X#3VariousBldg. 37Low pressure initial test runs, Test 3 is the only one we found data for
XB-98-1G #13-4-2017Crow Island, MA 
XB-98-1G #2 3-4-2017Crow Island  
XB-98-1G #3   
XB-98-1G #4   
XB-98-1G #5   
XB-98-1G #6   
XB-98-4G #13-24-2017Crow IslandUndetected stress concentrator in nozzle lead to a cracked nozzle.
XB-98-4G #24-2-2017Crow IslandPoor sealing on thermal liner lead to runaway burn-through
XB-98-4G #39-23-2017Crow IslandFull Duration

...