Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

 

Final Lines Diagram

Image Removed

 

Image Added

medusalinesdiagramMedusa Lines Diagram.pdfBooster

Lines

...

Line:Final Length:Calculations:

Main Riser

306 in

3*body length

Drogue Top Riser

306 in 

3*body length

Drogue Bottom Riser

408 in

4*body length

Staging Cone Riser

408 in

> Main Riser

Sustainer Lines:

Line:Final Length:Calculations:

Main Riser

291 in

3*body length

Drogue Top Riser

291 in 

3*body length

Drogue Bottom Riser

388 in

4*body length

Nose Cone Riser

388 in

> Main Riser

 

Preliminary Lines Diagram for full CO2 system

Image Removed

Initial Full Lines Diagram for CO2 Canister System

1Image Removed

Initial Full Lines Diagram for Piston System

 

Sizing 

 

Name

Length

Length from CDR (the corrected length)

Comments before CDR Lengths

Nosecone Riser

12 in

20 in

Better to make this 16 inches to make sure we clear the nose cone.

S Long Riser

200 in

190 in

We can also cut down on this a little - we just need it to

 be longer than nose cone riser + drogue riser + load-bearing riser which is 170 inches (using my suggested nose cone riser length) so maybe do that + 10 inches = 180 inches.

Also we need to add in extra length for TD+TD Loops.

S Drogue Riser

142 in

142 in

 

S Load Bearing Riser

12 in

12 in

 

S Main Riser

160 in

130 in

I think this is a bit long (we don't need to apply the same 4x body length rule for energy dissipation since we'll ideally be deploying under drogue) and the longer it is the higher risk we have for line tangling prior to main inflation. I would change this to maybe 130 inches.

S Motor Riser

50 in

50 in

 

Staging cone Riser

16.29 in

10 in

I think this can be a bit shorter given how short the staging cone is, maybe make this one 10 inches. 

B Long Riser

271.43 in

240 in

Same comment as above: just need it to be longer than staging cone riser + drogue riser + load-bearing riser which is 220 inches (using my suggested staging cone riser length) so maybe do that + 10 inches = 230 inches. We also need to add in extra length for TD+TD Loops.

B Drogue Riser

192.71 in

193 in

 

B Load Bearing Riser

16.29 in

17 in

 

B Main Riser

217.14 in

200 in

same as sus: I think this is a bit long (we don't need to apply the same 4x body length rule for energy dissipation since we'll ideally be deploying under drogue) and the longer it is the higher risk we have for line tangling prior to main inflation. I would change this to maybe 200 inches.

B Motor Riser

67.86 in

68 in

 

Notes:

Sustainer overall riser length: 204(drogue), 210in(main) → matches 70 inch body tube for sus

Booster overall riser length: 277 (drogue), 285in (main) → matches 95 inch body tube for booster

Want long riser > nosecone + drogue + load-bearing = 166 inches 

Need load-bearing risers + TD loops < main riser Image Removed