The pipe diameters and the source pressure are decided by us also, and the flow velocity is determined from the pipe area.
Helios Pressure Drop Calculations
We know the C_v constant for the valves, solenoids, and the injector so we can calculate the pressure drop across those components. Since we want to achive a certain pressure at the chamber, there is a certain required source pressure.