Value
Propellant Weight13.5 lbs
Impulse

Unknown

ClassificationUnknown
Delivered ispUnknown

Due to an unrecognized stress concentrator aligning with a sharp thermal gradient, the nozzle cracked during hotfire.

Video

Widget Connector
urlhttps://www.youtube.com/watch?v=x29jssYVqX8&feature=youtu.be

Data

 

Failure Analysis

3-24 Nozzle Failure.docx