Next meeting deliverables 01/02:
- Data output research or Type-T thermocouples, as defined by IEC Standards 61515, Emily Aleman Garcia ,
- Find other company to manufacture thermocouples multi-junction probe Emily Aleman Garcia
- Preliminary Pressure Sensor choice and Data output format Asael Acosta
- Preliminary Thermal Camera choice and Data output format Angelina Costa
- Learn/Investigate/Make progress on Cindy's deliverables list and what we specifically have to deliver Israel Garcia
Update notes:
- only one thermal camera on side profile
- two pressure sensors on axial placements
- New Thermocouple Choice from Emerson company
...
- Contacting companies for quote and data output specifications (specifically thermocouples)
- Choose Camera? Pressure Sensor?
- Update requirements in Nasa Systems Handbook format
Hi Angelina! Here's some things that are typical:
- Interface Requirements: UART (RS-422/485/232) or Ethernet
- Software Interface Control Document: details what is required to implement on Oligo's end in order to command your payload
For the Software ICD, some typical contents include:- Data Exchange Architecture (e.g., what data does the payload expect? at what frequency does it communicate? does data need to be stored? any security needs? ACK/NACK?)
- Physical Interface (more indepth info about the interface requirements)
- Data Rate of Communication
- Commanding Set (including data packet structure, state machines, failure modes, etc.)
- Expected Telemetry
- etc.
- Learn/Investigate/Make progress on Cindy's list:
Thermocouple Standards: