Requirements:
- Connect the motor to the mission package tube
- Hold the forward closure in place
- Withstand forces with a FoS of at least 2
- (forces on bottom face? forces on lip? depends on design choices, mass above frr, and bolt selection/pattern)
- From ppt:
- Withstand 88.96 kN upward force (on bottom face)
- Withstand 20.90 kN downward force (on lip)
Anticipated Maximum Forces:
- Upward Forces
- 86.2 kN
- Derived from anticipated maximum internal pressure and surface area of the FC
- Downward Forces
- 20.9 kN
- Derived from summing g-force and drag maximums
- 183.854 kg (Mass above FRR) * 122.03 m/s2 (max acceleration) = 20.67 kN
- Drag: 0.184 kN
- Min FoS Upward: 2.77
- Min FoS Downward: 12.0
- FEA (Max Displacement): 0.0001 in