In the bottom of this page you find the spectra, responses and background files necessary to reproduce the spectral analysis in Kettula et al., 2013 (A&A, 552, 47) which yielded results summarised in Fig 1. The results correspond to public SUZAKU calibration information in June 2011, i.e. XIS CALDB release
20110608\ and XRT CALDB release 20080709\

Fig.1: The average relative difference (diamonds) +- the error of the mean of the temperatures for different instrument pairs using the public calibration in June 2011 (blue line) and the modified contaminate used in the paper (red line) in the soft band.



  • SUZAKU data are processed with HEASoft3 release 6.11, containing Suzaku ftools version
    18 (see details).
  • XMM-Newton data are processed with xmmsas 20110223 1801-11.0.0 (see details).


  • The spectra are extracted from 3-6 arcmin annulus, centered on the cluster center
  • The scripts use a 1-temperature phabs x mekal model.
  • The column density is from Kalberla et al. (2005) and the absorption cross-sections are from  Balucinska-Church & McCammon (1992).
  • The scripts use the metal abundance table from Grevesse & Sauval (1998).



                               INDIVIDUAL FITS

                (Each cluster and instrument fitted separately, see Table A.1 in Kettula et al., 2013)

*Cluster*                                          *Instrument*

A1060            Suzaku/XIS0       Suzaku/XIS1      Suzaku/XIS3   

A1795            Suzaku/XIS0       Suzaku/XIS1      Suzaku/XIS3   

A262              Suzaku/XIS0       Suzaku/XIS1      Suzaku/XIS3   

A3112            Suzaku/XIS0       Suzaku/XIS1      Suzaku/XIS3   

A496              Suzaku/XIS0       Suzaku/XIS1      Suzaku/XIS3   

AWM7            Suzaku/XIS0       Suzaku/XIS1      Suzaku/XIS3   

Centaurus       Suzaku/XIS0       Suzaku/XIS1      Suzaku/XIS3   

Coma             Suzaku/XIS0       Suzaku/XIS1      Suzaku/XIS3   

Ophiuchus      Suzaku/XIS0       Suzaku/XIS1      Suzaku/XIS3   

Triangulum      Suzaku/XIS0       Suzaku/XIS1      Suzaku/XIS3   



The script files xisX_Y_3_6_am_circ_newcal_Z_mekalfit.xcm will set up the best fit. In more detail:

  • "X" refers to XIS unit (0,1, or 3)
  • "Y" is the cluster name
  • "Z" refers to the band used in the fit (0520 = 0.5-2.0 keV;  2070 = 2.0-7.0 keV





                                    JOINT FIT

                (For each cluster all XIS instruments fitted simultaneously, allowing Oxygen column density of the contaminant to vary, see Tables 5 and 6 in Kettula et al., 2013)


Part1

Running XSPEC script do_mekalfit_simult_modcon.xcm performs the spectral fits and produces

log files of the fit procedure  mekalfit_simult_modcon_Y.log

XSPEC session files mekalfit_simult_modcon_Y.xcm

and plots mekalfit_simult_modcon_Y.ps

of the best fits, where Y is the cluster name.

The local model for the contaminant (hcorat) is included in the distribution and will be set up automatically, provided your XSPEC has been installed from the source. 