To match conditions similar to those expected from the high speed flight, a blowtorch will be used to heat small samples while a thermocouple will monitor the surface temperature of the materials. After the test we will also be measuring the samples to estimate the ablation. A stand has been built to hold the propane blowtorch at a specific distance from the samples and a remote trigger mechanism allows operators to be a safe distance from the blowtorch and sample.

 The tests will be performed in a secure environment (blast chamber) and the operators will wear respirators during the tests. This document from Apogee Components was used as inspiration for this test procedure. Apogee Newsletter

Materials Used:

Below is the matrix for samples used in this thermal test.

 5-Layer Fiberglass10-Layer Fiberglass
Control (West Systems epoxy)  
West Systems + Phenolic microballoons  
West Systems + Cork microballoons  
West Systems + High temperature paint  
West Systems + Cotronics 4700  

Below is the test matrix for the parameters measured during this test. (Fill later with results).

Test Stand

<insert pics> 

Setting up thermocouples

 

Samples

Test Procedure:

Testing in blast chamber

Heat for 12 seconds

 