Test Breakdown
Date to be conducted: 3/16/2019
Time conducted:
Test Article: Test NC, from layup #1
Benchmark | Test Config. | Environmental Parameters | Criteria for Success |
---|---|---|---|
I. DAQ must be continuously operational under [TBD] F, [TBD] C |
| Records accurate temperatures (within expected 5 degree error, or allowable by reason) in SD Card and NAN Flash Memory for 8 min | |
II. Determine approximate thermal boundary conditions between inner wall and outer surface of NC at one selected node point |
| Records accurate temperatures for the node point (within expected 5 degree error, or allowable by reason) in SD Card and NAN Flash Memory for 7 min | |
III. Epoxy joints must survive continuous heating up to 8 minutes | Same as above | Sensor leads must feel secure when tugged after continuous heating. |
Results
Notes
3/13/2019 (Diane, Miske, Juan):
...