Water hammer concerns were raised by BlueShift engineers at the first hot fire attempt, suggesting threads might fail during hot fire. Hand calcs based on modified Hooke’s Law


LaTeX Math Block
anchor
alignmentleft
C=\sqrt{\frac{1}{\rho(1/K+D/(Ee))}}

and Joukowsky

LaTeX Math Block
anchor
alignmentleft
P=\rho CU

1[1K+DEe] and Joukowsky P=CU indicate 995 psi max pressure. SolidWorks FEA indicates 2.2 min factor of safety. https://www.fluidmechanics.co.uk/hydraulic-calculations/water-hammer-surge-analysis/

...