Water hammer concerns were raised by BlueShift engineers at the first hot fire attempt, suggesting threads might fail during hot fire. Hand calcs based on modified Hooke’s Law
| LaTeX Math Block | ||||
|---|---|---|---|---|
| ||||
C=\sqrt{\frac{1}{\rho(1/K+D/(Ee))}} |
and Joukowsky
| LaTeX Math Block | ||||
|---|---|---|---|---|
| ||||
P=\rho CU |
1[1K+DEe] and Joukowsky P=CU indicate 995 psi max pressure. SolidWorks FEA indicates 2.2 min factor of safety. https://www.fluidmechanics.co.uk/hydraulic-calculations/water-hammer-surge-analysis/
...