Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Migration of unmigrated content due to installation of a new plugin

Overview

Statistic
Value
Propellant Weight1.310 kg
Impulse

2113 2674 Ns

Maximum Pressure470 psi
ClassificationK373L467
Delivered isp155.2 204 s
Grains

PT-98 #11

This test used the a new nozzle, Characterization Nozzle #3, with a .48 in throat. We suspect The use of a damaged snubber caused a lag in the pressure data againin the first 0.5 seconds to be smoothed. There were no inhibited faces on this grain.

Video

Multimediawidget
urlhttps://www.youtube.com/watch?v=Krz2trA57yonamemotor6.mov

Data

#6.TXT

daqread.py