The fraction of the

...

annulus

...

defined by the inner

...

/outer

...

radius r_in

...

/r_out, which is covered by the extraction region of each instrument. For cross-calibration purposes, the measured fluxes must be divided by the numbers in table in order to extrapolate the fluxes to the full annulus.

Cluster       r_in      r_out            XMM-Newton/pn   pn     XMM-Newton/MOS   MOS    Chandra/ACIS

                 arcmin   arcmin          

A1795        1.5        2.7.7                0.88                        1.00                           1.00

A2029        1.5        2.5.5                0.89                        1.00                           1.00

A2052        1.7        2.5                    0.87                        0.98                           1.00

A2199        2.0        2.9 .9                0.82                        0.93                           1.00

A262          1.6        2.7.7                0.79                        0.91                           1.00

A3112        1.5        2.9.9                0.83                        0.95                           1.00

A3571        0.0        2.1                0.88                        0.94                           1.00

A85           1.5        3.0                0.85                        0.86                            0.84

Coma        1.0        5.0                0.93                        0.97                            0.88

HydraA      1.5        2.77                0.78                        0.86                           1.00

MKW3S     1.5        2.55               0.89                        1.00                            1.00