Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Time kept at 240 F: 10:00

Data:

Image Added

Conclusions:

DAQ survived test, recorded data onto SD card with minimal noise. Thermocouples feel secure after test. 

 

 

Oven Temperature Tracking:

...

 16.03-> ~240 F for a duration of 10 mins 


Test 2:

Setup:

Battery Voltage: 3.7 V

Time kept at 240 F: 

Data: Image Added

 Conclusions:

 

Notes

3/13/2019 (Diane, Miske, Juan):

...

3/16/2019 (Diane, Miske, Juan, Shreeyam):

  • Used four (4) masonry blocks to support NC in oven
  • Used normal PVC insulation wire for power, route through thermocouple inlet
  • Mounted daq with Kapton tape on a masonry block
  • Created a NC template of the top and base of the NC by marking a trace on the insulation 
  • Added Kaowool (ceramic based) insulation inside the base and top of the NC prior to oven insertion 
  • Discussed preheating oven to 257 F (125 C) before powering on

3/20/2019 (Diane, Miske, Juan, Shreeyam):

  • Decided to record data during preheating anyways for possible reference against mysterious data collection
  • Tagged thermocouples to match to attachment points in NC
  • Thermocouple Labeling
    • TC1 = White Dashed, TC2 = White Solid, TC3 = Black Dashed, TC4 = Black Solid, TC5 = Gold Dashed, TC6 = Gold Solid

Image Added