You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 17 Next »

Overview

Xaphan White was is a modified variant of the team's first composite propellant. It uses higher solids loading and fewer additives to achieve improved performance.

Find the Grain Log here.

Formula

Appropriately certified individuals can find the formula here.

Mixing

This records all of the mixings of this propellant performed by the team.

Mixing Date
Serial Numbers
Site
Result
9-29-201798-PT #1, #217-110First two 98 mm grains mixed. Improper equivalent weight calculation lead to soft cure.
11-7-201798-PT #317-110Mixing to characterize EZ-Cast. Used old mixer.
11-12-201798-PT #417-110Used old mixer. Improvements to casting process. Slightly lower solids loading
11-14-201798-PT #5-717-110First mixing with new mixer. 3 characterization grain for characterization testing.
11-22-201798-PT #8-1017-1103 grains for characterization testing. Stopped using EZ-Cast.
11-28-201798-PT #11, #1217-110Used finalized casting procedures
12-6-2017OW-152 #1, #217-110First 6 inch grains
12-8-2017OW-152 #3-517-110Next 3 6 inch grains

 

Testing

Test #
Date
Site
Result
Characterization Static Fire #1November 25, 2017Crow IslandNozzle Failure
Characterization Static Fire #2November 25, 2017Crow IslandNozzle Failure
Characterization Static Fire #3November 25, 2017Crow IslandMotor success, pressure transducer failure
Characterization Static Fire #4November 25, 2017Crow IslandMotor success
Characterization Static Fire #5December 2, 2017Crow IslandMotor Success! Highest pressure to date: 695 psi
Characterization Static Fire #6December 2, 2017Crow IslandSuccess, excellent BATES curve
OW-152-4G #1December 16, 2017Crow IslandPending